Product Overview
Rad-G™ Masimo Pulse Oximeter
with infant & pediatric/adult sensors
Complete Set
Back in stock now as a spot check only device, not as a continuous monitoring device. See more details here.
BEST SELLER for midwives performing pulse oximetry screening to check for critical congenital heart defects (CCHDs) in newborns.
Included in the box
- 1- Masimo Rad-G™ Pulse Oximeter (#95164)
- 1- RD SET YI SpO2 Pulse Oximeter Reusable Infant Sensor (>1 kg) & 6 Adhesive Wraps (#4653)
- 1- SpO2 "Fingerclip" Sensor for Pediatrics and Adults (#4325)
- 1- Multisite Foam Attachment Wraps (PACK OF 12) (#1602)
- 1- Rad-G Pulse Oximeter AC Power Adapter (to use to charge the unit)
This is a handheld battery operated pulse oximeter is outfitted for use with a reusable adult & infant sensor to use during a newborn heart screening and the "fingerclip" style pediatric & adult sensor for general use.
A rugged handheld device powered by clinically proven Masimo SET® pulse oximetry
- Strong external casing built to withstand drops from 6 ft. onto a hard surface.
- Light weight and slim profile allow for easy transport and storage.
- Internal rechargeable battery provides 24 hours of operational use.
- Operator's Manual - Note, now only available as a spot check device
Reliable Monitoring
Hospital-grade Masimo SET® Measure-through Motion and Low Perfusion™ pulse oximetry
Informative Display
Display of plethra waveform for additional information to use in patient assessment
Accuracy & Specifications
Specifications Hospital-grade Masimo SET® Pulse Oximetry ACCURACY ARMS4 Oxygen Saturation (SpO2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70–100%
No Motion Adults/Pediatrics/Infants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2%
Motion Adults/Pediatrics/Infants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low Perfusion Adults/Pediatrics/Infants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2%
Pulse Rate (PR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25–240 bpm
No Motion Adults/Pediatrics/Infants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 bpm
Motion Adults/Pediatrics/Infants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 bpm
Low Perfusion Adults/Pediatrics/Infants.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 bpm
Respiration Rate (RRp). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4–70 rpm
No Motion Adults/Pediatrics (>2 years of age). . . . . . . . . . . . . . . . . . . . . . . . . . . 3 rpm ARMS ,± 1 rpm mean error
PHYSICAL CHARACTERISTICS
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.27 kg. (0.59 lbs.)
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.4 cm x 19.8 cm x 2.5 cm (2.9” x 7.8” x 1.0”)
ENVIRONMENTAL Operating Temperature. . . . . . . . . . . . . . . . . . . While battery is charging: 0–40° C (32–104° F) While battery is NOT charging: 0–50° C (32–122° F)
BATTERY
Battery Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lithium ion
Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 hours